| VM ZINC® Compact roof |
|
Warm roof system combining VM ZINC® standing seam roofing with Foamglas® insulation.
Key advantages
 |
Completely vapour-proof: ideal system for buildings with very high hygrometry. |
 |
The absence of penetrating mechanical fixing eliminates any risk of thermal bridging. |
 |
VM ZINC PLUS (patented) protected on the underside. |
Areas of application
Roofing for buildings with high and very high hygrometry (swimming pools).
Main components
 |
VM ZINC® roofing |
| Packaging |
Small coils for profiling or preformed strips
on request |
| Surface aspects |
QUARTZ-ZINC PLUS |
| Thickness |
0.70 mm |
| Stretchout width |
500 mm |
Finished centre-to-centre
distance |
430 mm |
| Protective lacquer on inside |
60 microns on under surface
(lacquering process)
|
 |
Standing seam fixing clips
VM ZINC® Profile 1 fixed to galvanised steel plates with "Spedec" (SFS) screws supplied by VM ZINC®. |
 |
Geotextile separation membrane
(at least 100 g/sq. m).
Types:
|
|
. Gravifiltre (SIPLAST), |
|
. NTS 170 (SOPREMA) or equivalents. |
 |
Bituminous stress-distribution membrane
Types:
|
|
. Hyrène PS PY, gritted (AXTER), |
|
. Paradiène 20 SR4 (SIPLAST), |
|
. Sopralène Flam S 180-30 (SOPREMA). |
 |
Non-perforating fixing plates
Galvanised steel: 150-x 150 mm, 1mm thick. They are fixed into the supporting insulation and the standing seam clips are screwed into them.
|
 |
Foamglas® T4 thermal insulation
Types:
|
|
. aluminosilicate non-compressible cellular foamglass panels, forming a vapour barrier. |
|
. 60 x 45 cm thickness varies depending on thermal insulation requirements. |
|
|
|